Build your own horizontal aluminium fence or privacy screen from stock lengths. Use this checklist to work out what to buy, then cut and assemble the parts yourself. A bay is one panel between two posts or other suitable supports.
Want us to do the cutting? Choose the cut-to-size horizontal panel instead. Posts and accessories are sold separately.
1. Plan your bays
- Sketch the fence and mark each end, corner or shared intermediate post. A straight run of three bays needs four posts if both ends are freestanding. Where a suitable existing wall or post can support a panel, the side frame can mount directly to it.
- Choose 65 mm or 90 mm horizontal slats and the gap between them. Multiply the number of slats by the slat width and add one fewer gap than slats. Allow separately for the 3 mm side-frame top cap and any clearance below the panel.
- Measure each clear opening between supports at the top, middle and bottom. Use the smallest measurement and follow the horizontal assembly guide (PDF) for the cut allowance. Test-fit one slat before cutting the rest, particularly if using F-section or exposed-end caps.
- Work out how many pieces fit in each full length. Allow for saw cuts, end trimming and offcuts. Check the stock length and finish on each product page before ordering.
Post size, span and fixings depend on the screen height, wind exposure and what you’re fixing to. For exposed or unusual installations, get suitable advice before ordering. This guide covers privacy screens and fencing, not balustrades or pool barriers.
2. Add posts and mounting hardware
-
Posts
Choose 50 × 50 mm posts or 65 × 65 mm posts to suit the installation. Count shared posts only once. -
One top cap per post
The listed 2.4 m posts include a cap. For posts cut from full lengths, add matching 50 mm post caps or 65 mm post caps separately. -
Surface-mounted posts
Add one matching 50 mm base plate set or 65 mm base plate set per post. The included screws attach the plate to the post; buy suitable anchors for the mounting surface separately. -
Finish the post base
For a base plate, add 50 mm two-piece covers or 65 mm two-piece covers if you want to hide the anchors. For a post set into concrete instead of on a base plate, 50 mm dress rings or 65 mm dress rings are optional trim at the surface. Match the trim to your post size.
Posts and mounting products
50 × 50 mm posts
Options load as you scroll.
65 × 65 mm posts
Options load as you scroll.
50 mm post caps
Options load as you scroll.
65 mm post caps
Options load as you scroll.
50 mm base plate set
Options load as you scroll.
65 mm base plate set
Options load as you scroll.
50 mm two-piece covers
Options load as you scroll.
65 mm two-piece covers
Options load as you scroll.
50 mm dress rings
Options load as you scroll.
65 mm dress rings
Options load as you scroll.
3. Add the parts for each horizontal bay
-
Slats
Choose 65 mm full-length slats or 90 mm full-length slats. Both are sold in stock lengths; check the selected finish for the available length. -
Two side frames per bay
Cut two uprights from Quickscreen side frame (5.8 m stock). An intermediate post between two bays takes a frame on each side. Allow separate fixings to attach the frames to the post or wall. -
Two fixing covers per bay
Cut two matching lengths from the separate snap-on fixing cover (5.8 m stock). These conceal the slat screws. -
Two side-frame top caps per bay
Add one pack of side-frame top caps for each bay. These are different from post caps. -
Spacers for the chosen gap
Add spacer blocks (50 per pack). For a standard panel, allow one spacer at each end of each gap. No spacer is needed for a zero-gap layout. -
Slat screws
Add 10G × 16 mm wafer screws (100 per pack). Count a fixing at both ends of each slat, plus any extra fixings for a centre support or F-section. Wall, post and ground fixings are separate.
Horizontal panel products
65 mm full-length slats
Options load as you scroll.
90 mm full-length slats
Options load as you scroll.
Quickscreen side frame
Options load as you scroll.
Snap-on fixing cover
Options load as you scroll.
Side-frame top caps
Options load as you scroll.
Spacer blocks
Options load as you scroll.
10G × 16 mm wafer screws
Options load as you scroll.
4. Add extras only if your layout needs them
-
Wide bays
For a standard horizontal bay wider than 2 m, the assembly guide calls for a vertical centre support rail. Its snap-on cover is included. Ask us for the matching rail top cap and any support brackets needed for your layout. -
No access from above?
Add Quickscreen F-section when fitting a pre-assembled panel into a void. Follow Appendix 1 of the assembly guide; the F-section works with the side frames, not in place of them. -
Angled slats or fence returns
For louvred bays, use 65 mm fixed louvre bracket pairs and follow Appendix 2. The centre support isn’t compatible with fixed louvres; keep those bays to 2 m or less. For a 45° change in fence direction, see the 135° adapter. -
Exposed slat ends
Standard side frames conceal the slat ends. Add 65 mm slat end caps or 90 mm slat end caps only where ends are exposed and the layout allows for the caps. Each pack contains four.
Optional products
Centre support rail
Options load as you scroll.
Quickscreen F-section
Options load as you scroll.
65 mm fixed louvre bracket pairs
Options load as you scroll.
135° adapter
Options load as you scroll.
65 mm slat end caps
Options load as you scroll.
90 mm slat end caps
Options load as you scroll.
5. Add a ProScreen gate
Measure the clear opening between the finished posts, not post-centre to post-centre. Check it at the top, middle and bottom. Use the smallest measurement for planning, and make sure both posts are plumb and the opening is square before ordering.
As a starting point, allow 20 mm on the hinge side and 20 mm on the latch side. Check those clearances against your chosen hardware before ordering. The width you enter is the finished gate width, not the opening width.
Example: 1,000 mm clear opening − 20 mm hinge gap − 20 mm latch gap = 960 mm finished gate width. Allow clearance below the gate and check the highest ground point across its swing when choosing your finished height.
Choose your gate size, finish and slat options on the kit listing. Check that your selected hinges and latch are included or add them separately. The gate is cut to order and supplied as a flat-pack kit.
Configure the ProScreen Horizontal Gate Kit (opens in a new tab)
Example: two straight bays
For two freestanding bays with 1,800 mm clear openings, using 16 × 65 mm slats per bay and 9 mm gaps:
- Posts: 3 posts, with 3 post caps if not included. Add mounting hardware and covers if surface mounting.
- Frame pieces: 4 side frames, 4 covers and 4 side-frame caps (2 packs). At this panel height, one 5.8 m stock length of each extrusion covers the four cuts.
- Slats: 32 cut pieces. If you get three pieces from each stock length after allowing for cuts and trimming, buy 11 lengths.
- Spacers and screws: 60 spacers (2 packs) and 64 slat screws (1 pack). Add your post or wall fixings separately.
The slat stack is about 1,175 mm high before the top cap and any ground clearance. This is a quantity example, not a site-specific span or fixing recommendation.
Shop all Quickscreen components · Download the assembly guide (PDF) · Ask Slatwerx about your layout